Victron Energy arrow Victron Isolation Transformer arrow Isolation Transformer 3600w 115/230V 32/16A



Isolation Transformer 3600w 115/230V 32/16A

VITR0362040
Price: £599.00
£509.15
You Save: 15.00%
(plus vat @ 17.5.%)

Print Screen

The isolation transformer eliminates any electrical continuity between AC shore power and the boat.

It is essential for safety and eliminates the need for galvanic isolators and polarity alarms

Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc.that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIªs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

The best solution

to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an isolation transformer to connect to the shore-side supply.

It is a misunderstanding

Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion . Bringing only the live and neutral wire on board results in an unsafe situation because GFCIªs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.



 







Your Basket

Show Cart
Your Cart is currently empty.

Kuranda Newsletter

Sign up now.. we send out special offers only via our newsletters...






Online Offers

Aqua Filta
Aqua Filta
£29.33
£24.93
You Save: 15.00%
24/3000/70 Phoenix MultiPlus
24/3000/70 Phoenix MultiPlus
£1 640.00
£1 394.00
You Save: 15.00%
Quattro 24/5000/120
Quattro 24/5000/120
£2 733.00
£2 323.05
You Save: 15.00%
Kuranda UK Ltd, Kuranda House, Forge Road, Whaley Bridge, High Peak SK23 7HY. Co Reg: 4361623
Whilst Kuranda UK Ltd make every effort to maintain the accuracy of the information on this web site, it cannot accept responsibility for any claim, loss or damage
which may occur from the use of the information contained within this site.
Joomla Templates by JoomlaShack Joomla Templates
SSL